syngo DynaCT Cardiac

syngo DynaCT Cardiac
 
Get a Quote

syngo DynaCT Cardiac utilizes images acquired from one rotational angiography run to display the 3D morphology of the ROI. Image acquisition is achieved in 5 seconds after injection of contrast agent into the ROI. The 3D image is obtained by 3D reconstruction on the syngo Workplace and is available for assessment in the lab within a couple of seconds after image acquisition.

Regardless of whether syngo DynaCT Cardiac is used with or without ECG-triggering, the three-dimensional cardiac morphology can be displayed as

  • Volume rendering technique visualization
  • Surface model (by using advanced segmentation algorithms)
     

syngo DynaCT Cardiac without ECG-triggering

syngo DynaCT Cardiac utilizes images acquired from one rotational angiography run to display the 3D morphology of the left atrium. Image acquisition is achieved in approx. 5 seconds after direct injection of contrast agent into the pulmonary artery. The 3D image is obtained by 3D reconstruction on the syngo X Workplace and is available for assessment in the EP lab within less than 20 seconds after image acquisition.

Regardless of whether syngo DynaCT Cardiac is used with or without ECG-triggering, the three-dimensional cardiac morphology can be displayed as

  • Volume rendering technique visualization
  • Surface model (by using advanced segmentation algorithms of syngo Electrophysiology Guidance)
  • Endoscopic view ("Fly") visualization

Additionally it is possible to visualize the detailed cardiac anatomy within cross-sectional images (MPRs).
 


syngo DynaCT Cardiac with ECG-triggering

syngo DynaCT Cardiac utilizes images acquired from one or multiple ECG-triggered rotational angiography runs to display the 3D morphology of the heart. Image acquisition is performed during application of contrast agent in approx. 20 seconds.


The 3D image is obtained by 3D reconstruction including retrospective ECG-gating on the syngo X Workplace. The 3D image is available for assessment in the EP lab within less than 3 minutes after image acquisition.

Regardless of whether syngo DynaCT Cardiac is used with or without ECG-triggering, the three-dimensional cardiac morphology can be displayed as

  • Volume rendering technique visualization
  • Surface model (by using advanced segmentation algorithms of syngo Electrophysiology Guidance)
  • Endoscopic view ("Fly") visualization.

Additionally it is possible to visualize the detailed cardiac anatomy within cross-sectional images (MPRs).

General Requirements

System

Minimum Software Version

syngo X Workplace: VB11
syngo MMWP: 2008A
AXIOM Artis: VB31
Artis zee: VC12

Other

Only for detector systems 20cm x 20cm
and 30cm x 40cm
Please note: On account of certain regional limitations of sales rights and service availability, we cannot guarantee that all products included in this website are available through the Siemens sales organization worldwide. Availability and packaging may vary by country and are subject to change without prior notice. Some/All of the features and products described herein may not be available in all countries.