With Tim 4G and Dot, MAGNETOM Aera maximizes productivity up to 50%.1 At the same time, MAGNETOM Aera also delivers excellent patient-centered care. A full range of advanced and routine applications make MAGNETOM Aera your top-of-the-line choice for 70 cm 1.5T to expand your service lines beyond boundaries.

“With MAGNETOM Aera, we are confident we have one of the most advanced 1.5T MRI systems available on the market today.2
Prof. Christoph Bremer, MD
Head of the Department of Radiology
St. Franziskus Hospital, Münster, Germany


Deliver exceptional quality and speed in MRI.

Tim is Siemens’ proven integrated coil technology with more than 10,000 installations worldwide.

Now in its 4th generation, Tim 4G enables:
4G Flexibility. 4G Accuracy. 4G Speed.

  • Up to 204 coil elements. Up to 64 RF channels.
  • Exceptional SNR and image quality with Tim 4G’s high-channel coils and the unique RF architecture enabling DirectRF for true signal purity.
  • Excellent image quality with up to 40% reduction of scan times.3

Faster patient set-up

Tim technology accelerates patient set-up and provides high patient comfort. The Tim 4G SlideConnect® and DirectConnect® coils along with the Tim Dockable Table accelerate patient set-up even further.

Tim 4G DirectConnect and SlideConnect enable high patient comfort and ease-of-use thanks to:

  • Faster connections
  • Easier set-up

 

Tim Dockable Table – mobility done right

  • Fast patient preparation even outside of examination room
  • Integrated Spine coil
  • Easy transport
  • Optimized comfort for immobile patients
  • Holds up to 250 kg/550 lb to accommodate more patients

“The MAGNETOM Aera’s detachable table is beneficial as it is easier for transferring bed patients, such as those with cord compression and for use in emergency situations. Radiographers are benefiting from the system’s ease-of-use and appreciate the integrated coil technology which is making for faster scans without compromising on image quality.”2

Kim Robertson
Head of Radiology Service
Guy’s Hospital, U.K.


Go for consistent results, efficiently.

Siemens set the benchmark in MR scanning and productivity by introducing Dot. DotGO4 is Siemens’ next step in MRI exam software, combining intuitive protocol management with quality results for each exam. For true flexibility, consistency, and efficiency.

Flexibility. Consistency. Efficiency.

  • Intuitive protocol management with one central and flexible user interface
  • Quality results for each exam, consistent and reproducible
  • Up to 20% shorter exam slots for more efficiency in MRI5

“On average, we were able to shorten the examination from 25 to 20 minutes per patient.”2
Anton Quinsten, RT, Senior MRI Technologist
Institute of Diagnostic Radiology and Neuroradiology
University Hospital Essen, Germany


Expand your MRI services.

Accommodate more patients, get more referrals, and increase your patients’ satisfaction. Improve your marketability with quieter exams, 70 cm Open Bore, and ultra-short 145 cm system design and trendsetting applications.

New requirements and indications in MRI today are driven by

  • demographic shift
  • rise of chronic diseases
  • fast pace of innovation

Trendsetting applications

MAGNETOM Aera therefore offers a comprehensive and unique portfolio of trendsetting applications. Now available on MAGNETOM Aera, brand-new applications with syngo MR E114 helping you to expand your range of MRI services.

FREEZEit6 – our embrace motion technology – makes MRI faster and more robust than it has ever been, even in the most challenging cases. It opens up the wide field of body imaging.

TWIST-VIBE6
Always the right contrast in dynamic liver imaging

TWIST-VIBE combines for the first time high temporal and excellent spatial resolution with full coverage for precision in dynamic liver MRI. It is reliable imaging from the very first shot, making time-consuming and costly repeat exams a thing of the past, always assuring correct contrast timing in dynamic liver imaging.
(Image: University Hospital Saarland, Homburg, Germany)

StarVIBE6
Free-breathing, contrast-enhanced body imaging

In the past, contrast-enhanced body MRI wasn’t an option for patients who have difficulties holding their breath. Now, with StarVIBE, they can breathe freely throughout the scan. The application intelligently resists motion artifacts, resulting in faster and more accurate exam results for a range of new patient populations.
(Image of 2-year-old male7: University Hospital Saarland, Homburg, Germany)

Advanced WARP4,8

The Advanced WARP functionality lets you serve rapidly-growing patient populations with artificial joints. The benefits are substantial: Infections can be diagnosed earlier and there’s a significant gain in image quality.
(Image: Mount Sinai Hospital, Toronto, Canada)

MyoMaps4

MyoMaps generates comprehensive pixel-based T1, T2, and T2* colored parametric maps on the fly, providing you for the first time an additional layer of valuable diagnostic information about even subtle changes in tissue composition.
(Image: National Institutes of Health, Bethesda, USA)

syngo MR E11


Maximized patient satisfaction

Make your patients’ scan experience as comfortable as possible. Maximize your patients’ comfort, cooperation, and satisfaction with:

The roominess of the 70 cm Open Bore

Super-short system (145 cm) for more exams with the patient’s head outside the bore

Tim Dockable Table for faster patient set-up outside the room, e.g. for immobile patients

Lightweight coil design and Illumination MoodLight® for relaxed patients

Experience up to 97% reduction in sound pressure for whole routine exams – with no need to compromise image quality.1 Quiet Suite4 lets you attract more patients by offering quieter routine examinations for neurology and orthopedics.

 

  • Complete, quiet exams for neurology and orthopedics
  • No compromises in image quality
  • Up to 97% reduction in sound pressure1

 


Maximized sustainability

Life Design is the Siemens MRI design philosophy. Since the beginning, the guiding principle in our MRI development has been to design our systems around the life of you and your patients. Life Design saves you money from the time of installation.

  • DirectRF concentrates all transmit and receive components at the magnet, and requires very little of your expensive floor space
  • Zero Helium boil-off and optimized cooling system (Eco Chiller)
  • Green Cooling Package (optional) to decrease energy consumption for cooling
  • Optimize your performance and workflow efficiency with customized service offerings
  • EVOLVE provides a comprehensive suite of software and hardware updates to help you to keep pace with the rapidly developing technological advances

 

Produkty, usługi i zasoby powiązane

1Results may vary. Data on file.

3Based on the scan time difference between a 30-channel set-up and an 18-channel set-up with otherwise identical parameters and same SNR. Data on file.

4The product may not be commercially available in all countries. Due to regulatory reasons its future availability cannot be guaranteed. Please contact your local Siemens organization for further details.

5University Hospital Essen, Brain Dot Engine Workflow Study, GER

6May not be commercially available in countries outside the U.S., future availability cannot be guaranteed.

7MR scanning has not been established as safe for imaging fetuses and infants under two years of age. The responsible physician has to decide about the benefit of the MRI examination in comparison to other imaging procedures.

8The MRI restrictions (if any) of the metal implant must be considered prior to patient undergoing MRI exam. MR imaging of patients with metallic implants brings specific risks. However, certain implants are approved by the governing regulatory bodies to be MR conditionally safe. For such implants, the previously mentioned warning may not be applicable. Please contact the implant manufacturer for the specific conditional information. The conditions for MR safety are the responsibility of the implant manufacturer, not of Siemens.